UNVENTED (VENT-FREE)
PROPANE/LP GAS LOG HEATER
CGG2618P,
CGG3324P(T), and
CGG3630P
Thermostat and
Variably-Controlled Models
(Variable Manually-Controlled Models Also Designed-Certified as
Vented Decorative Appliances)
OWNER’S OPERATION AND INSTALLATION MANUAL
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury, or loss of life.
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor’s phone. Follow the
gas supplier’s instructions.
If you cannot reach your gas supplier,
call the fire department.
Installation and service must be per-
formed by a qualified installer, ser-
vice agency, or the gas supplier.
WARNING: Improper installation, adjust-
ment, alteration, service, or maintenance
can cause injury or property damage.
Refer to this manual for correct installa-
tion and operational procedures. For as-
sistance or additional information con-
sult a qualified installer, service agency,
or the gas supplier.
WARNING: This appliance is for instal-
lation only in a solid-fuel burning ma-
sonry or UL127 factory-built fireplace,
or in an approved ventless firebox. It is
design-certified for these installations
in accordance with ANS Z21.11.2. Ex-
ception: Do not install this appliance in
a factory-built fireplace that includes
instructions stating it has not been
tested or should not be used with
unvented gas logs.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in
which it is installed. Provisions for adequate combustion and ventilation air must be
provided. Refer to
Air for Combustion and Ventilation
section on page 4 of this manual.
This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by
state or local codes.
* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer
Przeglądanie stron 0
1 2 3 4 5 6 ... 29 30

Podsumowanie treści

Strona 1 - PROPANE/LP GAS LOG HEATER

Save this manual for future reference.UNVENTED (VENT-FREE)PROPANE/LP GAS LOG HEATERCGG2618P,CGG3324P(T), andCGG3630PThermostat andVariably-Controlled

Strona 2 - INFORMATION

10103425UNVENTED (VENT-FREE) GAS LOG HEATERINSTALLING HEATER BASEASSEMBLY WARNING: If installing in asunken fireplace, special care isneeded. You must

Strona 3

11103425OWNER’S MANUALINSTALLATIONInstallation Items Needed• hardware package (provided with heater)• approved flexible gas hose (not provided)(if all

Strona 4 - VENTILATION

12103425UNVENTED (VENT-FREE) GAS LOG HEATERTee JointPipeNippleCap3" MinimumSediment TrapGasRegulatorFrom ExternalRegulator(11" W.C.** to14&q

Strona 5

13103425OWNER’S MANUALPressure Testing Gas SupplyPiping SystemTest Pressures In Excess Of 1/2 PSIG1. Disconnect heater and its individualmanual shutof

Strona 6 - 12"

14103425UNVENTED (VENT-FREE) GAS LOG HEATER WARNING: Failure to positionthe parts in accordance with thesediagrams or failure to use onlyparts specifi

Strona 7 - Right Sides

15103425OWNER’S MANUALOPERATINGHEATERThermostat-ControlledModelsFigure 21 - Control Knob and IgnitorButton LocationPILOTOFFLOHI1. STOP! Read the safet

Strona 8 - Material

16103425UNVENTED (VENT-FREE) GAS LOG HEATERNote: Home owners generally prefer tooperate their heater with the chimneydamper closed. This will put all

Strona 9

17103425OWNER’S MANUAL4. Wait five (5) minutes to clear out anygas. Then smell for gas, includingnear the floor. If you smell gas,STOP! Follow “B” in

Strona 10 - INSTALLATION

18103425UNVENTED (VENT-FREE) GAS LOG HEATERCLEANING ANDMAINTENANCE WARNING: Turn off heaterand let cool before cleaning. CAUTION: You must keepcontrol

Strona 11 - OWNER’S MANUAL

19103425OWNER’S MANUALTROUBLESHOOTING WARNING: Turn off and un-plug heater and let cool beforeservicing. Only a qualified ser-vice person should servi

Strona 12

2103425UNVENTED (VENT-FREE) GAS LOG HEATER WARNING: Any change tothis heater or its controls can bedangerous.1. This appliance is only for use with th

Strona 13

20103425UNVENTED (VENT-FREE) GAS LOG HEATEROBSERVED PROBLEMOne or both burners do not light after ODS/pilot is litDelayed ignition of one or both burn

Strona 14

21103425OWNER’S MANUALTROUBLESHOOTINGContinuedIMPORTANT: Operating heater where impurities in air exist may create odors. Cleaningsupplies, paint, pai

Strona 15

22103425UNVENTED (VENT-FREE) GAS LOG HEATERAdhesive-backedMounting ClipFigure 34 - Locating Thermostat SensingBulb on Masonry FireplaceThermostatSensi

Strona 16 - OPERATING

23103425OWNER’S MANUALTECHNICALSERVICEYou may have further questions about in-stallation, operation, or troubleshooting.If so, contact DESA Internatio

Strona 17

24103425UNVENTED (VENT-FREE) GAS LOG HEATERILLUSTRATEDPARTSBREAKDOWNVARIABLE MANUALLY-CONTROLLED MODELSCGG2618PCGG3324PCGG3630P18201926252121275678292

Strona 18 - INSPECTING

25103425OWNER’S MANUALPARTS LISTVARIABLE MANUALLY-CONTROLLED MODELSCGG2618PCGG3324PCGG3630PThis list contains replaceable parts used in your heater.

Strona 19

26103425UNVENTED (VENT-FREE) GAS LOG HEATERILLUSTRATEDPARTSBREAKDOWNTHERMOSTAT-CONTROLLED MODELSCGG3324PT56256789101188291312131415161817192426277-17-

Strona 20 - TROUBLESHOOTING

27103425OWNER’S MANUALPARTS LISTTHERMOSTAT-CONTROLLED MODELCGG3324PTThis list contains replaceable parts used in your heater. When ordering parts, fol

Strona 21

28103425UNVENTED (VENT-FREE) GAS LOG HEATERPARTS CENTRALSThese Parts Centrals are privately owned busi-nesses. They have agreed to support ourcustomer

Strona 22 - SENSING BULB

29103425OWNER’S MANUALNOTES___________________________________________________________________________________________________________________________

Strona 23

3103425OWNER’S MANUALLOCAL CODESInstall and use heater with care. Follow alllocal codes. In the absence of local codes, usethe latest edition of The N

Strona 24 - BREAKDOWN

KEEP THIS WARRANTYWARRANTY INFORMATIONModelSerial No.Date PurchasedLIMITED WARRANTYCOMFORT GLOW VENT-FREE PROPANE/LP GAS LOG HEATERSDESA International

Strona 25

4103425UNVENTED (VENT-FREE) GAS LOG HEATERAIR FORCOMBUSTION ANDVENTILATIONToday’s homes are built more energy efficientthan ever. New materials, incre

Strona 26

5103425OWNER’S MANUALAIR FORCOMBUSTION ANDVENTILATIONContinuedDETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONDetermining if You Have a Confined or Unco

Strona 27

6103425UNVENTED (VENT-FREE) GAS LOG HEATERAIR FORCOMBUSTION ANDVENTILATIONContinuedVENTILATION AIRVentilation Air From InsideBuildingThis fresh air wo

Strona 28 - ACCESSORIES

7103425OWNER’S MANUALINSTALLATION WARNING: A qualified ser-vice person must install heater.Follow all local codes. WARNING: Before installingin a prev

Strona 29

8103425UNVENTED (VENT-FREE) GAS LOG HEATERIf Using MantelYou must have noncombustible material(s)above the fireplace opening. Noncombus-tible material

Strona 30 - WARRANTY INFORMATION

9103425OWNER’S MANUALMinimum Non-Combustible Material Minimum Non-Combustible Material Height Distances to Underside ofMantel Top of FireplaceOpeningU